CyberIndexBeta

Evidence for this value

Subject
Stormshield SNi Series
What it says
Has this capability
Confidence
1
Valid from
5 Nov 2026
Recorded
5 Nov 2026
Recorded value
OT Virtual Patching: partial

Evidence

  • supportsenbitcon.deVendor websitesCorroborated source
    https://www.enbitcon.de/media/d1/91/4b/1722343329/SNS-EN-SNi20-Datasheet.pdf
    The SNi20 datasheet lists 'Intrusion detection and prevention' among its protections and 'Vulnerability detection (option)' as an add-on, over a deep-packet-inspection list that covers Modbus, UMAS, S7, EtherNet/IP, CIP, OPC UA, BACnet/IP, PROFINET, IEC 60870-5-104 and IEC 61850. Limited rather than native because the datasheet names intrusion prevention and vulnerability detection but no signature feed for known flaws in industrial equipment. For redundancy the datasheet's own REDUNDANCY heading gives only 'Bypass (safety mode)', and its safety mode covers 'cluster, bypass and power supply' — no industrial ring protocol.
    Retrieved 5 Nov 2026

History

Correcting a value records the new one and dates the old one — nothing is overwritten, so you can see what this page said before, and when it changed.

  • 5 Nov 2026OT Virtual Patching: partialcurrent

May we count your visit? CyberIndex would like to use Google Analytics to see which pages are read. It sets cookies and sends your visit to Google. Decline and nothing is loaded — the site works the same either way. Privacy.